Atlas Copco2901001600 replacement
2901001600 (standard format 2901-0016-00) is an oil stop valve / oil check valve repair kit (Oil Stop Valve Kit / Check Valve Kit) specifically for oil-injected screw air compressors.
Core Function
• Working Principle and Value:
◦ Prevent oil injection during shutdown:
Quickly cut off the oil circuit the moment the air compressor shuts down or unloads, preventing lubricating oil in the oil-gas separator tank from flowing back into the compressor main unit (airend) under back pressure, so as to avoid lubricating oil spraying out from the air inlet or causing an oil-laden heavy-load start next time.
◦ Ensure lubrication on startup:
Open the oil circuit in a timely manner when the compressor starts up, guaranteeing that a stable oil film and oil pressure are rapidly established for rotors and bearings, and preventing costly mechanical damage to the main unit caused by oil shortage, dry grinding or cavitation.
Kit Composition and Appearance Features
Based on the original assembly drawings and physical part list, this repair kit is an all-in-one preventive maintenance package, which usually contains the following wearable components:
• Metal valve core and hexagonal end cap (silver/brass precision machined parts)
• Return coil spring (high-strength fatigue-resistant spring that controls the valve opening and closing pressure)
• Oil-resistant sealing ring / O-ring (usually made of green or black fluororubber / nitrile rubber to ensure sealing of high-temperature oil circuits)
Maintenance Cycle and Replacement Timing
• Recommended replacement cycle:
Usually replaced together with the regular Preventive Maintenance of the air compressor at 4,000 hours or 8,000 hours.
• Common failure symptoms (inspection and replacement shall be carried out immediately if the following conditions occur):
◦ Oil spraying or oil fume emitting outward from the air filter when the air compressor shuts down.
◦ Abnormally high exhaust temperature or slow build-up of oil circuit pressure during equipment operation.
◦ Stagnation caused by fatigue fracture of the internal spring of the valve or aging and swelling of the O-ring