Part numbers marked "replacement" are not affiliated with the original manufacture. Part numbers and pictures are used for cross reference only.
Description
Application
Atlas Copco2906018200 replacement
2906018200 is 4000-hour preventive maintenance kit (4000H Maintenance Kit) designed specifically for oil-free air compressors. This kit integrates all original wear parts and sealing consumables required for a single scheduled maintenance under one standard order number, to ensure the air tightness, oil circuit cleanliness and output efficiency of the compressor during long-cycle operation.
Typical Component Composition
Since compressors of the same series have minor differences across production years and configuration versions, the detailed list shall be subject to the official spare parts manual corresponding to the equipment serial number. A standard 4000-hour maintenance kit generally includes the following categories of core consumables:
• Filtration system components.
Including Gearbox Oil Filter Elements and Air Filter Elements, which are used to trap mechanical impurities and ensure the cleanliness of air entering the compression chamber.
• Seals and connecting parts.
Including various high-temperature and oil-resistant O-rings, Gaskets and Lip Seals, used to restore the sealing performance of pipelines and valves after disassembly, assembly and maintenance.
• Valve parts and vulnerable accessories.
Depending on the configuration of the specific sub-model, it may contain vulnerable repair assemblies for check valves, drain valves or temperature control valves (Lubricating oil is usually purchased separately as an independent consumable and is not included in standard filter and seal kits).
Core Specifications and Positioning
• Applicable Equipment.
Primarily for stationary oil-free air compressors, with focused compatibility for the ZR/ZT 75–90 series (both water-cooled ZR and air-cooled ZT models are covered).
• Maintenance Interval.
Scheduled for the routine Grade A / annual preventive maintenance milestone when the equipment accumulates 4,000 operating hours or reaches 1 year of service, whichever comes first.